Summary for Test 2020-01-30-16-1

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214653
DEA: 050K3304
EFIS: 0512000068
DIST-CO-RTE-PM05-SB-101-45.5/45.5
Award DateNot set
Closeout DateNot set
Work DescriptionGaviota Culvert Replacement
Location DescriptionOn Rte 101 in Santa Barbara County, near Gaviota State Park and just South of Gaviota Safety Roadside Rest Area
QA Service Level1 (Verified on 01/30/2020)

Sample Information

Sample Taken Date01/30/2020 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/30/2020
Sample typePer Request A brief description of the sampleNative Soil
The quantity of what the sample constitutesOne Culvert From where was the sample collectedOther
First name of sampler or witnessed byJacob Last name of sampler or witnessed byBerven
Title of sampler Telephone number of sampler
Laboratory sample identification20-D-008 Linked DIME Sample ID
The fabricator/manufacturer/facility nameExisting Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2020-01-30-16
DIME Test ID: 2020-01-30-16-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-01-31

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Measured
Tester's full name: Daniel Gingras
Date of test: 01/31/2020
Soil sample resistance (lab measure 1): 8400 Ohms
Soil sample resistance (lab measure 2): 3200 Ohms
Soil sample resistance (lab measure 3): 2100 Ohms
Soil sample resistance (lab measure 4): 2100 Ohms
Soil sample resistance (lab measure 5): 2700 Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 2100 Ohms
Soil sample temperature: 21 C
Soil box constant: 1
pH of soil: 7.38
Minimum soil resistance corrected to 15.5: 2388.75 Ohms
Minimum soil resistivity at 15.5: 2389 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/31/2020