Summary for Test 2020-01-27-17-2

Test performed: ASTM A970-15e1

Project Information

Project IdentifiersProject ID: 213856
DEA: 112888U4
EFIS: 1118000199
DIST-CO-RTE-PM11-SD-11,125,905-Various
Award Date05/09/2019
Closeout Date09/14/2023
Work DescriptionCONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date01/27/2020 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing01/31/2020
Sample typeQuality Assurance A brief description of the sample#14 ASTM 706 41'-4" Both Ends Headed Bar H55
The quantity of what the sample constitutes4 samples from Lot # 1 From where was the sample collectedFabricator
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byMarin
Title of samplerInspector Telephone number of sampler951-500-0685
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameIntegrity Rebar Placers Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form133-010-20 Structure unique identifier
Structure nameS125/905 Connector

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)65021892 Head Manufacturer Lot Number(s)Lot 1
Rebar Size14 Headed Bar Model NameNA
Size of HeadFull Size - 9x Head Connection TypeForged
Head ShapeCircular Rebar ManufacturerGerdau
Head ManufacturerIntegrity Rebar Placers Head FabricatorIntegrity Rebar Placers
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Test Details

DIME Sample ID: 2020-01-27-17
DIME Test ID: 2020-01-27-17-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-01-29

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/29/2020
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
112.2521147493988Ok neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 1/29/2020