Summary for Test 2020-01-23-2-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 214245
DEA: 11404604
EFIS: 1114000049
DIST-CO-RTE-PM11-SD-56-5.6
Award Date10/21/2019
Closeout Date03/01/2022
Work DescriptionCONSTRUCT 2 LANES, STRUCTURAL CONCRETE BRIDGE.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO AT 0.5 MILE WEST OF CAMINO DEL SUR UNDERCROSSING
QA Service Level1 (Verified on 12/23/2019)

Sample Information

Sample Taken Date01/23/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeQuality Assurance A brief description of the sampleFlash welded hoops
The quantity of what the sample constitutes114 Available from Lot 1 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byWeeks
Title of samplerASI Telephone number of sampler310-883-8369
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Etiwanda Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL79-007-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4092869
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop5'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC
Welding CompanyCMC Etiwanda Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2020-01-23-2
DIME Test ID: 2020-01-23-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-01-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/27/2020
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1338/25mm0.7977175.2497690Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 1/30/2020