Summary for Test 2020-01-06-25-4

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 213764
DEA: 080F0304
EFIS: 0800020358
DIST-CO-RTE-PM08-SBD-60-R0.7/R3.0
Award Date03/07/2019
Closeout Date07/27/2023
Work DescriptionREMOVE AND REPLACE THREE OVERCROSSING BRIDGES ON ROUTE 60
Location DescriptionIN SAN BERNARDINO COUNTY IN AND NEAR CHINO AT VARIOUS LOCATIONS FROM O.1 MILE WEST OF PIPELINE AVENUE OVERCROSSING TO 0.1 MILE EAST OF BENSON AVENUE OVERCROSSING
QA Service Level1 (Verified on 05/01/2019)

Sample Information

Sample Taken Date01/06/2020 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing01/10/2020
Sample typeVerification A brief description of the sample(2) Spliced Strands (2) Non-Spliced
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byRigo Last name of sampler or witnessed byMarin
Title of samplerQA Telephone number of sampler951-500-0685
Laboratory sample identificationCal Trans Lab Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California Corporation Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL133-001-20 Structure unique identifier
Structure namePipeline Bridge Girder

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S378762-6 Number of Coils1
Group Number Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0507819 Mfg. Lot Number(s)N/A
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2020-01-06-25
DIME Test ID: 2020-01-06-25-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2020-01-24

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/24/2020
UTM: 120KIP
Temperature: 72 f
Extensometers: NA
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0507819S378762-60.21557628001.53bewing

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 1/24/2020