Summary for Test 2020-01-17-3-3

Test performed: ASTM D624-00-re12

Project Information

Project IdentifiersProject ID: 214394
DEA: 101C8604
EFIS: 1016000023
DIST-CO-RTE-PM10-SJ-4-R16.8/R17.4
Award Date10/28/2019
Closeout Date07/15/2021
Work DescriptionREPAIR BRIDGE HINGE.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF MADISION STREET TO 0.2 MILE WEST OF AIRPORTWAY UNDERCROSSING
QA Service Level1 (Verified on 09/13/2019)

Sample Information

Sample Taken Date01/17/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/21/2020
Sample typeQuality Assurance A brief description of the sampleelastomeric bearing pad
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byHoward Last name of sampler or witnessed bySternberg
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)18508-1
Material/Compound/Elastomer IDna Samples Representing27
Description (size)3.5x12x14 CommentsUnknown
Description (Number of Shims)7 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch Numberna

Test Details

DIME Sample ID: 2020-01-17-3
DIME Test ID: 2020-01-17-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2020-01-28

Test Results


Number of specimens tested: 3
Input Type: Measured
Tester's full name: randelin
Date of test: 01/23/2020
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.07
Sample 1 Tear Strength: 219.2
Sample 2 Median Thickness: 0.074
Sample 2 Tear Strength: 218.8
Sample 3 Median Thickness: 0.073
Sample 3 Tear Strength: 217.6
UTM: 2kip
Median of the Tear Strength Values: 218.8 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 2

Source: Bluehill Data Point File
Test graph for Sample 3

Source: Bluehill Data Point File
Test graph for Sample 1

Test was verified on 1/28/2020