Summary for Test 2020-01-08-3-6

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 214175
DEA: 030H4804
EFIS: 0315000198
DIST-CO-RTE-PM03-SAC-99-0.1/1.6,11.8/21.6
Award Date08/20/2019
Closeout Date08/11/2023
Work DescriptionCOLD PLANE AC PAVEMENT AND RHMA OVERLAY.
Location DescriptionSACRAMENTO COUNTY IN AND NEAR GALT FROM DRY CREEK BRIDGE TO SIMMERHORN ROAD AND IN ELK GROVE AND SACRAMENTO FROM 0.9 MILE SOUTH OF ELK GROVE BOULEVARD TO MARTIN LUTHER KING JR BOULEVARD
QA Service Level1 (Verified on 05/29/2019)

Sample Information

Sample Taken Date01/08/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/16/2020
Sample typeQuality Assurance A brief description of the sampleA563 DH HDG Nuts
The quantity of what the sample constitutes230 From where was the sample collectedManufacturer
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Telephone number of sampler9165170532
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameEDSCO Fasteners Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-002-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)190483 Nut Mfg. Lot Number(s)DEBL
Washer Mfg. Lot Number(s) Bolt SpecificationNA
Bolt Length(s)Unknown Nut SpecificationA563 DH
Washer SpecificationNA FinishHDG
Diameter/Size2.5" Bolt Mfg. Lot NumberN/A
Rocap Test Requirement(s)No Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2020-01-08-3
DIME Test ID: 2020-01-08-3-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-01-22

Test Results


Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 01/22/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: DEBL
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DH D/N 2H
Size: 2.5 in
Bolt Length: no data
Measurement Average: 5.13 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/22/2020