Summary for Test 2020-01-17-3-1
Test performed: ASTM D2240-05re10Project Information
Project Identifiers | Project ID: 214394 DEA: 101C8604 EFIS: 1016000023 |
---|---|
DIST-CO-RTE-PM | 10-SJ-4-R16.8/R17.4 |
Award Date | 10/28/2019 |
Closeout Date | 07/15/2021 |
Work Description | REPAIR BRIDGE HINGE. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT VARIOUS LOCATIONS FROM 0.1 MILE EAST OF MADISION STREET TO 0.2 MILE WEST OF AIRPORTWAY UNDERCROSSING |
QA Service Level | 1 (Verified on 09/13/2019) |
Sample Information
Sample Taken Date | 01/17/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2020 |
Sample type | Quality Assurance | A brief description of the sample | elastomeric bearing pad |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Howard | Last name of sampler or witnessed by | Sternberg |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Scougal Rubber | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | 18508-1 |
---|---|---|---|
Material/Compound/Elastomer ID | na | Samples Representing | 27 |
Description (size) | 3.5x12x14 | Comments | Unknown |
Description (Number of Shims) | 7 | Type of Bearing Pad | Steel |
Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Scougal Rubber |
Batch Number | na |
Test Details
DIME Sample ID: 2020-01-17-3
DIME Test ID: 2020-01-17-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2240-05re10: Standard Test Method for Rubber Property - Durometer Hardness
Test Release Date: 2020-01-28
Test Results
Input Type: Measured
Tester's full name: Rheanna Andelin
Date of test: 01/22/2020
Temperature: 72 f
Humidity: 50 %
Reading #1: 52
Reading #2: 55
Reading #3: 54
Reading #4: 54
Reading #5: 54
Mean: 53.8
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/28/2020 ✔