Test 2020-01-01-10-3 (ASTM D36-14ε1) Summary

Project Information
Project IdentifiersProject ID: 213943
DEA: 051G5704
EFIS: 0515000049
DIST-CO-RTE-PM05-SLO-58-0.7/1.9
Work DescriptionCOLD PLANE AC, PLACE RHMA-G AND RECONSTRUCT CURB RAMPS.
Location DescriptionSAN LUIS OBISPO COUNTY AT SANTA MARGARITA FROM 0.7 MILE EAST OF ROUTE 101/58 SEPARATION TO J STREET
Sample Information
Sample Taken Date1/1/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeQuality Control A brief description of the sampleARB
The quantity of what the sample constitutes0 From where was the sample collectedOther
First name of sampler or witnessed byMr Last name of sampler or witnessed byWitness
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameNational Blending Company Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradeNot set Lot numberNot set
Sublot numberNot set HMA Design ID JMF3512-2020-156-G2214H830
Test Details
DIME Sample ID: 2020-01-01-10
DIME Test ID: 2020-01-01-10-3
Testing Lab: CT D05 - Field Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2020-01-17
Test Results

ASTM Thermometer used?: 15C
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 01/01/2020
Bath Liquid:freshly boiled distilled water
General comments (publicly viewable) (Max 250 characters):

Test was verified on 01/17/2020