Test 2020-01-09-1-4 (ASTM A970-15e1) Summary

Project Information
Project IdentifiersProject ID: 213749
DEA: 120C1104
EFIS: 1200000633
DIST-CO-RTE-PM12-ORA-57-20.3/21.6
Work DescriptionWIDEN BRIDGES AND CONSTRUCT RW, SW, HMA, JPCP AND ELECTRICAL SYSTEMS.
Location DescriptionORANGE COUNTY IN BREA FROM 0.6 MILE SOUTH TO 0.7 MILE NORTH OF LAMBERT ROAD UNDERCROSSING
Sample Information
Sample Taken Date1/9/2020 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing1/10/2020
Sample typeQuality Assurance A brief description of the sample#10/32mm. HRC 120 T Heads
The quantity of what the sample constitutes48 From where was the sample collectedSource
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)9001747 Head Manufacturer Lot Number(s)1
Rebar Size10 Headed Bar Model NameHRC 120
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel California
Head ManufacturerNucor Head FabricatorNucor
Material Standard CodeASTM A706
Test Details
DIME Sample ID: 2020-01-09-1
DIME Test ID: 2020-01-09-1-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-01-14
Test Results

Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/13/2020
UTM: 400kip
Temperature:72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
111.2712561498908Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 01/14/2020