Summary for Test 2019-12-16-1-3

Test performed: ASTM D624-00-re12

Project Information

Project IdentifiersProject ID: 214231
DEA: 051M1704
EFIS: 0519000077
DIST-CO-RTE-PM05-SLO-1-71.5/72, 71.5/72.0
Award Date04/17/2019
Closeout Date08/17/2022
Work DescriptionPolar Star Emergency wall and viaduct; NOTE ON FUNDING: This is an emergency project, per PM, METS (unit 3652) is covered for work on this project under WBS 270.44. Any issues with funding please notify METS Rep.
Location DescriptionNot set
QA Service Level1 (Verified on 06/28/2019)

Sample Information

Sample Taken Date12/16/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/06/2020
Sample typeAcceptance A brief description of the sample1x8x12 Bearing Pad
The quantity of what the sample constitutes32 From where was the sample collectedSource
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Telephone number of sampler9165170532
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS19-450-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)18465-1
Material/Compound/Elastomer ID55 Duo Samples Representing32
Description (size)1x8x12 Comments
Description (Number of Shims)2 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch Number18465-1

Test Details

DIME Sample ID: 2019-12-16-1
DIME Test ID: 2019-12-16-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2020-01-14

Test Results


Number of specimens tested: 3
Input Type: Measured
Tester's full name: randelin
Date of test: 01/08/2020
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.085
Sample 1 Tear Strength: 219
Sample 2 Median Thickness: 0.077
Sample 2 Tear Strength: 214.5
Sample 3 Median Thickness: 0.075
Sample 3 Tear Strength: 231.3
UTM: 2kip
Median of the Tear Strength Values: 219 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 2

Source: Bluehill Data Point File
Test graph for Sample 3

Source: Bluehill Data Point File
Test graph for Sample 1

Test was verified on 1/14/2020