Test 2020-01-03-4-2 (ASTM A615-15) Summary

Project Information
Project IdentifiersProject ID: 214109
DEA: 081H6404
EFIS: 0817000094
DIST-CO-RTE-PM08-SBD-210-R26.5
Work DescriptionWIDEN RAMP & CONSTRUCT RETAINING WALL.
Location DescriptionSAN BERNARDINO COUNTY IN SAN BERNARDINO AT EASTBOUND HIGHLAND AVENUE EXIT RAMP
Sample Information
Sample Taken Date1/3/2020 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing1/7/2020
Sample typeQuality Assurance A brief description of the sampleThreaded Rebar Coupler
The quantity of what the sample constitutes2 From where was the sample collectedDistributor
First name of sampler or witnessed byClaudio Last name of sampler or witnessed byHunger
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameStresstell Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size8
Nut Specification for Threaded BarNA System ManufacturerStresstell
Epoxy Coating ColorNA Threaded Bar ApplicationSoil Nail
Coating StandardsUncoated Bar Heat Number(s)NA
Nut Heat Number(s)NA Bar Lot NumberNA
Nut Lot NumberNA Coupler Heat Number(s)DL18106338
Coupler Grade75
Test Details
DIME Sample ID: 2020-01-03-4
DIME Test ID: 2020-01-03-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2020-01-08
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 01/08/2020
UTM: 400kip
Temperature:72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
1No.8/25mm0.79115413926900Coupler Test Only, A615 GR75fsaylor

General comments (publicly viewable) (Max 1000 characters): Coupler Test Only, A615 GR75
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.

Test was verified on 01/08/2020