Test 2019-12-11-45-1 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
Sample Information
Sample Taken Date12/11/2019 Sample Unique Key45
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/11/2019
Sample typeAcceptance A brief description of the sample3/8" AGGREGATE
The quantity of what the sample constitutes2 BAGS From where was the sample collectedDistributor
First name of sampler or witnessed byZaid Last name of sampler or witnessed byAbdelkhaliq
Title of samplerTET Laboratory sample identification8972
The fabricator/manufacturer/facility nameSECURITY PLANT LA-MIRADA Transportation Laboratory (TL) NumberC914390
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Unknown
The fabricator's/manufacturer's product name for the sample3/8 inch aggregate The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberG3-19-PCC-001 Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2019-12-11-45
DIME Test ID: 2019-12-11-45-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-03-17
Test Results

What size aggregate is being tested?: 0.5 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: LARRY DIAZ
Date of test: 12/14/2019
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:97 %
Cumulative percent passing the #4 sieve:25 %
Cumulative percent passing the #8 sieve:6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 03/17/2020