Summary for Test 2019-12-11-30-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 213741 DEA: 07325704 EFIS: 0716000089 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-1.7 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | BUILDING CONSTRUCTION IN LOS ANGELES COUNTY IN SANTA FE SPRINGS AT 14044 FREEWAY DRIVE. |
Location Description | Santa Fe Springs, At 14044 Freeway Drive. |
QA Service Level | 1 (Verified on 07/08/2019) |
Sample Information
Sample Taken Date | 12/11/2019 | Sample Unique Key | 30 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Quality Assurance | A brief description of the sample | F1554 Anchor Bolt |
The quantity of what the sample constitutes | 108 EA | From where was the sample collected | Distributor |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Weeks |
Title of sampler | ASI | Telephone number of sampler | 310-883-8369 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-195-19 | Structure unique identifier | |
Structure name | Building Work |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 3063603 | Nut Mfg. Lot Number(s) | 413065A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F1554 Gr. 55 |
Bolt Length(s) | 10" | Nut Specification | A563 Gr. DH |
Washer Specification | N/A | Finish | Plain |
Diameter/Size | 5/8" with 3" hook | Bolt Mfg. Lot Number | N/A |
Rocap Test Requirement(s) | NA | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-12-11-30
DIME Test ID: 2019-12-11-30-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-12-17
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/16/2019
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | 413065A | 40033 | Nut Proof |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 12/17/2019 ✔