Summary for Test 2019-12-04-1-3
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 213702 DEA: 041G4304 EFIS: 0412000126 |
---|---|
DIST-CO-RTE-PM | 04-NAP-128-R7.4 |
Award Date | 03/29/2019 |
Closeout Date | 12/08/2022 |
Work Description | REPLACE BRIDGE, HMA PAVING, DRAINAGE AND RSP |
Location Description | NAPA COUNTY NEAR SAINT HELENA AT CONN CREEK |
QA Service Level | 1 (Verified on 07/29/2019) |
Sample Information
Sample Taken Date | 12/04/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/09/2019 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" x 3.5" F3125 A325 HS Bolts |
The quantity of what the sample constitutes | 33 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-410-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 100786902 | Nut Mfg. Lot Number(s) | N/A |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | F3125 A325 |
Bolt Length(s) | 3.5" | Nut Specification | N/A |
Washer Specification | N/A | Finish | HDG |
Diameter/Size | 1/2" | Bolt Mfg. Lot Number | G9426 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2019-12-04-1
DIME Test ID: 2019-12-04-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2019-12-11
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 12/10/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: G9426
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 N
Size: .5 in
Bolt Length: 3.5 in
Measurement Average: 4.77 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/11/2019 ✔