Test 2019-12-04-11-1 (ASTM F606-14a) Summary

Project Information
Project IdentifiersProject ID: 214329
DEA: 120S2404
EFIS: 1220000002
DIST-CO-RTE-PM12-ORA-91-6.42/6.5
Work Descriptionrepair a damage steel girder by heat straightening as a result of a high load vehicle hit
Location DescriptionWestbound Route 91 at La Palma Avenue Bridge Structure at PM 6.42
Sample Information
Sample Taken Date12/4/2019 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/9/2019
Sample typeQuality Assurance A brief description of the sample7/8"-9 x 3-1/4" F3125
The quantity of what the sample constitutes16 From where was the sample collectedOther
First name of sampler or witnessed byKenneth Last name of sampler or witnessed byVarela
Title of samplerAssociate Steel Inspector Laboratory sample identification
The fabricator/manufacturer/facility nameNucor Fastener Division Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL08-067-19 Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)100892131 Nut Mfg. Lot Number(s)401062A
Washer Mfg. Lot Number(s)032492 Bolt SpecificationASTM F3125
Bolt Length(s)3-1/4 Nut SpecificationASTM A563 Gr. DH
Washer SpecificationASTM 436 FinishMG
Diameter/Size7/8"-9 Bolt Mfg. Lot Number411380A
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes
Test Details
DIME Sample ID: 2019-12-04-11
DIME Test ID: 2019-12-04-11-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-12-11
Test Results

Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/10/2019
UTM:450kip
Temperature:no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A411380A0.875067093298.4510.00A325 Wedge Tensilespaine

General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 12/11/2019