Test 2019-04-01-42-7 (AASHTO T210-15) Summary

Project Information
Project IdentifiersProject ID: 9999
DEA: 00000000
EFIS: 0000000000
COOP: 99999333399
MINOR: 333333
Permit Numbers: 555555 0400NRT0000
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Sample Information
Sample Taken Date4/1/2019 Sample Unique Key42
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing4/1/2019
Sample typeVerification A brief description of the sample1/2" Virgin Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byBarrett Last name of sampler or witnessed byFelder
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameGriffith Edmonston Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)04-03447
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2019-86
Test Details
DIME Sample ID: 2019-04-01-42
DIME Test ID: 2019-04-01-42-7
Testing Lab: CT HQ - Hot Mix Asphalt Laboratory
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Test Release Date: 2019-12-02
Test Results

Which test procedure(s) is/are used?: Procedure A and Procedure B
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 04/01/2019
Was strict temperature control maintained?: Yes
What type of water was used?: Distilled
Height of sediment column: 0.6 in
Clay reading: 4.9 in
Sand reading: 3.8 in
Durability Index (coarse):82
Durability Index (fine):78
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/02/2019