Summary for Test 2019-11-12-13-7

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 214397
DEA: 120N3204
EFIS: 1213000196
DIST-CO-RTE-PM12-ORA-91-R9.8/R18.9
Award Date11/07/2019
Closeout Date07/01/2022
Work DescriptionCONST PRECAST SLAB REPLACEMENT, COLD PLANE AC PVMT AND PLACE RHMA.
Location DescriptionORANGE COUNTY IN ANAHEIM AND YORBA LINDA FROM 0.3 MILE WEST OF LAKEVIEW AVENUE OVERCROSSING TO RIVERSIDE COUNTY LINE
QA Service Level1 (Verified on 12/02/2019)

Sample Information

Sample Taken Date11/12/2019 Sample Unique Key13
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/14/2019
Sample typeVerification A brief description of the sample1/2 RHMA-G-SP
The quantity of what the sample constitutesJMF 3 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byRJ Noble Orange Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0683G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHanson Aggregates, Mayhew Aggregates Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Hanson Aggregates, Mayhew Aggregates
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample50R003ARSPO
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at RJ Noble Orange Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-11-12-13
DIME Test ID: 2019-11-12-13-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-05-07

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Danilo Ferrer
Date of test: 11/21/2019
Weighted percentage of particles (by mass) that were flat and elongated: 8 %
Weighted percentage of particles (by mass) that were not flat and elongated: 92 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/7/2020