Summary for Test 2019-10-31-3-6
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 213808 DEA: 080N6704 EFIS: 0800000536 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-28.1/37.4 |
Award Date | 03/12/2019 |
Closeout Date | 04/28/2022 |
Work Description | CONSTRUCT RAISED MEDIAN AND LEFT TURN LANES. |
Location Description | RIVERSIDE COUNTY NEAR HEMET FROM 0.6 MILE EAST OF ROUTE 215 TO 0.4 MILE WEST OF ACACIA AVENUE. |
QA Service Level | 1 (Verified on 12/04/2019) |
Sample Information
Sample Taken Date | 10/31/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/01/2019 |
Sample type | Verification | A brief description of the sample | 3/4 HMA-A-SP R24 |
The quantity of what the sample constitutes | JMF 7 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | California Commercial Asphalt Lake Elsinore | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0670A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Chander Aggregates Corona, Lake Elsinore | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0098, 91-33-0011 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R24 | The fabricator/manufacturer designation for the sample | 53417315 |
The plant number | Unknown | A detailed description of where the material sample was collected | Bet Cut at California Commercial Asphalt Lake Elsinore Plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-10-31-3
DIME Test ID: 2019-10-31-3-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-05-07
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Edmond Jabbour
Date of test: 11/05/2019
Clay Level (Test 1): 6
Sand Level (Test 1): 4
Clay Level (Test 2): 7.8
Sand Level (Test 2): 4.2
Clay Level (Test 3): 7
Sand Level (Test 3): 4
Sand Equivalent (Test 1): 67
Sand Equivalent (Test 2): 54
Sand Equivalent (Test 3): 58
Sand Equivalent: 60
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/7/2020 ✔