Summary for Test 2019-10-18-5-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date10/18/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/21/2019
Sample typeQuality Assurance A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byekene Last name of sampler or witnessed byEzeoke
Title of samplerTET Telephone number of sampler
Laboratory sample identification934-1018 Linked DIME Sample ID
The fabricator/manufacturer/facility namena Transportation Laboratory (TL) Number20191018
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameE st and I15 Victorville

Material Information

Material TypeConcrete The concrete mix design numberna
The truck number from where the sample was collectedna The batch plant ticket number from where the sample was collectedna
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleSKANSKA AMES
A detailed description of where the material sample was collected28 cy lcb Where the material sample would have been placed if not sampledE st and I15 Victorville
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-10-18-5
DIME Test ID: 2019-10-18-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-11-04

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 10/25/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 28750 lb
Maximum load on cylinder 2: 30060 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 1013.4 psi
Compressive strength of cylinder 2: 1056.2 psi
Compressive strength (to nearest 10 psi): 1030 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/4/2019