Test 2019-10-29-29-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 214136
DEA: 010F3604
EFIS: 0115000115
DIST-CO-RTE-PM01-HUM-101-R39.2/R48.3
Work DescriptionCOLD PLANE AC PAVEMENT, RHMA OVERLAY, AND GUARDRAIL INSTALLATION.
Location DescriptionHUMBOLDT COUNTY NEAR REDCREST, PEPPERWOOD, AND STAFFORD FROM ENGLWOOD PARK UNDERCROSSING TO EEL RIVER BRIDGE AND OVERHEAD
Sample Information
Sample Taken Date10/29/2019 Sample Unique Key29
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/29/2019
Sample typeQuality Control A brief description of the sampleRockdust
The quantity of what the sample constitutesJMF From where was the sample collectedManufacturer
First name of sampler or witnessed byMatt Last name of sampler or witnessed byHorn
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameMercer Fraser B Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-12-0002::SANDY PRAIRIE
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedstockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown HMA Design ID JMF3512-2019-142-19-213RHMA-SP
Test Details
DIME Sample ID: 2019-10-29-29
DIME Test ID: 2019-10-29-29-1
Testing Lab: Trinity Engineering Laboratories, Inc. - Fresno
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-10-29
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Calculated
Tester's full name: Matthew Horn
Date of test: 10/29/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:100 %
Cumulative percent passing the 1/4 in. sieve:100 %
Cumulative percent passing the #4 sieve:98 %
Cumulative percent passing the #8 sieve:53 %
Cumulative percent passing the #16 sieve:40 %
Cumulative percent passing the #30 sieve:33 %
Cumulative percent passing the #50 sieve:25 %
Cumulative percent passing the #100 sieve:17 %
Cumulative percent passing the #200 sieve:10 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/29/2019