Summary for Test 2019-09-27-5-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 213436 DEA: 010J1304 EFIS: 0118000174 |
---|---|
DIST-CO-RTE-PM | 01-HUM-VAR- |
Award Date | Not set |
Closeout Date | 07/20/2021 |
Work Description | REPAIR OIL LINES AT BRACUT & WILLOW CREEK MS |
Location Description | HUM - VARIOUS |
QA Service Level | 1 (Verified on 08/24/2018) |
Sample Information
Sample Taken Date | 09/27/2019 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/30/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolts, nuts and washers |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | C740751 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-196-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 403168A | |
Washer Mfg. Lot Number(s) | 0619-188 | Bolt Specification | A325 |
Bolt Length(s) | 2 | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | .875 | Bolt Mfg. Lot Number | 160850A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-09-27-5
DIME Test ID: 2019-09-27-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-10-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 10/02/2019
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | 403168A | 70191 | Nut Proof | bewing |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 10/2/2019 ✔