Summary for Test 2019-09-05-30-1
Test performed: ASTM D92-12bProject Information
Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 09/05/2019 | Sample Unique Key | 30 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/05/2019 |
Sample type | Quality Control | A brief description of the sample | 3/4 inch RHMA-G SP WMA |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | Marina | Last name of sampler or witnessed by | Kamel |
Title of sampler | Telephone number of sampler | 707-259-5708 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Syar Lake Herman | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Modifier | Asphalt Modifier Type | Unknown |
---|---|---|---|
Asphalt Modifier Mix Number | Not set |
Test Details
DIME Sample ID: 2019-09-05-30
DIME Test ID: 2019-09-05-30-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: ASTM D92-12b: Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester (Flash Point)
Test Release Date: 2020-12-10
Test Results
Unit system used?: SI Units
Ambient Barometric Pressure unit?: mm Hg
Input Type: Calculated
Tester's full name: Lake Herman Lab
Date of test: 09/05/2019
Corrected Flash Point: 216 C
General comments (publicly viewable) (Max 1000 characters): Asphalt Modifier - ASTM D92
Test was verified on 12/10/2020 ✔