Test 2019-09-19-10-7 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date9/19/2019 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing9/20/2019
Sample typeVerification A brief description of the sample3/4" Aggregate for a RHMA-G JMF
The quantity of what the sample constitutesJMF Prequalification Program From where was the sample collectedManufacturer
First name of sampler or witnessed byRahshaun Last name of sampler or witnessed bySpears
Title of samplerTransportation Engineer Laboratory sample identification
The fabricator/manufacturer/facility nameSyar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-48-0002::LAKE HERMAN QUARRY
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedFrom the plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2019-09-19-10
DIME Test ID: 2019-09-19-10-7
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-09-30
Test Results

Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 09/26/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500.6 grams
Mass of the pycnometer with water and aggregate (C): 979.1 grams
Mass of the pycnometer with water (B): 667.2 grams
Mass of the oven dried sample (before pycnometer) (A): 481.1 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.6 grams
Mass of the oven dry aggregate (for absorption) (A): 481.1 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.550
Bulk specific gravity (SSD Basis):2.653
Apparent specific gravity:2.843
Absorption:4.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/30/2019