Summary for Test 2019-09-18-2-3

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212596
DEA: 100L0204
EFIS: 1013000053
DIST-CO-RTE-PM10-SJ,STA-99-0.0-0.7:24.4-24.8
Award Date11/30/2018
Closeout Date07/15/2021
Work DescriptionPartial Bridge Replacement
Location DescriptionON ROUTE 99 IN RIPON AT THE COUNTY LINE OF SAN JOAQUIN COUNTY AND STANISLAUS COUNTY AT THE STANISLAUS RIVER BRIDGES (29-0013L/R).
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date09/18/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2019
Sample typeQuality Assurance A brief description of the sampleAnchor Rod Assembly
The quantity of what the sample constitutes56 From where was the sample collectedFabricator
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerQuality Assurance Inspector Telephone number of sampler916-826-6371
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDS Brpwn Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS47-031-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)188896, 21817790, DL17100129 Nut Mfg. Lot Number(s)Nucor
Washer Mfg. Lot Number(s)Technical Stamping Inc Bolt SpecificationASTM F1554 Gr 105
Bolt Length(s)25 inches Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishHDG
Diameter/Size1-1/8 inch Bolt Mfg. Lot NumberAlton Steel Inc
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-09-18-2
DIME Test ID: 2019-09-18-2-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-09-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/26/2019
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11402840A116453Nut Proofbewing

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/27/2019