Summary for Test 2019-09-05-10-1

Test performed: ASTM F606-14a

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/05/2019 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/09/2019
Sample typeStock A brief description of the sample1"-8 x 36" DES Galvanized, 8"thread one end, 6" thread one end
The quantity of what the sample constitutes249 From where was the sample collectedManufacturer
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCALTRANS METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameA and M Nut and Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-062-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3085623 100896087 188268 Nut Mfg. Lot Number(s)422061A
Washer Mfg. Lot Number(s)314461 Bolt SpecificationASTM F1554-15 Gr. 55-S1
Bolt Length(s)36" Nut SpecificationASTM A194
Washer SpecificationF436 FinishGalvanized
Diameter/Size1" Bolt Mfg. Lot Number47383-PPO
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-09-05-10
DIME Test ID: 2019-09-05-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-09-20

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 09/18/2019
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11422061A91526Nut Proofbewing

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/20/2019