Test 2019-09-06-16-2 (ASTM F606-14) Summary

Project Information
Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
Sample Information
Sample Taken Date9/6/2019 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/17/2019
Sample typeQuality Assurance A brief description of the sampleA449 HDG All Thread Stud
The quantity of what the sample constitutes5 From where was the sample collectedSource
First name of sampler or witnessed byJoe Last name of sampler or witnessed byLanz
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameUSI Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)DL15105872 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationA449
Bolt Length(s)42" Nut SpecificationNA
Washer SpecificationNA FinishF2329
Diameter/Size.875 Bolt Mfg. Lot Number28930-B
Rocap Test Requirement(s) Lubricant Requirements(s)
Test Details
DIME Sample ID: 2019-09-06-16
DIME Test ID: 2019-09-06-16-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-09-18
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 09/18/2019
UTM:450kip
Temperature:72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
12UNC 7/8 0.462621746217413457611947255196A449 All Threaded Stud

General comments (publicly viewable) (Max 250 characters): A449 All Threaded Stud
Test Graph
Source: Bluehill Data Point File

Test was verified on 09/18/2019