Summary for Test 2019-06-27-26-8

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214339
DEA: 081G0004
EFIS: 0815000107
DIST-CO-RTE-PM08-RIV-95-14.5/35.6
Award Date11/04/2020
Closeout Date03/01/2022
Work DescriptionCONSTRUCT CONCRETE/RSP APRONS
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS FROM 4 MILES NORTH OF PALO VERDE DAM ROAD TO 0.6 MILE SOUTH OF SAN BERNARDINO COUNTY LINE
QA Service Level1 (Verified on 12/02/2020)

Sample Information

Sample Taken Date06/27/2019 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/28/2019
Sample typePreliminary A brief description of the sampleSoil obtained from depth of 5'
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byJose Last name of sampler or witnessed byGuzman
Title of samplerMREA Telephone number of sampler
Laboratory sample identification8631 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) Number8631
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRte 95, PM 24.79, Outside shoulder
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-06-27-26
DIME Test ID: 2019-06-27-26-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-09-12

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Tess Perez
Date of test: 07/08/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 13000 Ohms
Soil sample temperature: 22.8 C
Soil box constant: 1
pH of soil: 8.52
Minimum soil resistance corrected to 15.5: 15373 Ohms
Minimum soil resistivity at 15.5: 15373 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/12/2019