Summary for Test 2019-08-27-11-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 212011
DEA: 07252624
EFIS: 0700021272
DIST-CO-RTE-PM07-LA-5-R45.4/R61.2
Award Date04/17/2017
Closeout Date01/25/2021
Work DescriptionREHABILITATE CONCRETE PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN LOS ANGELES AND AT CASTAIC FROM 0.2 MILE SOUTH OF ROUTE 14/5 SEPARATION TO 0.7 MILE NORTH OF PALOMAS WASH BRIDGE
QA Service Level1 (Verified on 05/03/2017)

Sample Information

Sample Taken Date08/27/2019 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/30/2019
Sample typeVerification A brief description of the sample1/2 RHMA-G-SP
The quantity of what the sample constitutesPSE 4 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byJohn Last name of sampler or witnessed byDong
Title of sampler Telephone number of sampler
Laboratory sample identification0510G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample1/2 RHMA-G-SP The fabricator/manufacturer designation for the sample106836
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at All American San Fernando Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-08-27-11
DIME Test ID: 2019-08-27-11-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-10-15

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Sebastian Ferrer, Satish Jain
Date of test: 09/03/2019
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 94 %
Cumulative percent passing the 3/8 in. sieve: 79 %
Cumulative percent passing the 1/4 in. sieve: 53 %
Cumulative percent passing the #4 sieve: 36 %
Cumulative percent passing the #8 sieve: 16 %
Cumulative percent passing the #16 sieve: 9 %
Cumulative percent passing the #30 sieve: 6 %
Cumulative percent passing the #50 sieve: 4 %
Cumulative percent passing the #100 sieve: 3 %
Cumulative percent passing the #200 sieve: 1.8 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/15/2019