Summary for Test 2019-07-26-16-12
Test performed: CTM 217-June 2011Project Information
Project Identifiers | Project ID: 212603 DEA: 07304604 EFIS: 0714000073 |
---|---|
DIST-CO-RTE-PM | 07-LA-105-R0.5/R18.0 |
Award Date | 11/09/2017 |
Closeout Date | 01/28/2021 |
Work Description | UPGRADE EXISTING TRANSPORTATION MANAGEMENT SYSTEM ELEMENTS. |
Location Description | LOS ANGELES COUNTY FROM ROUTE 1/105 SEPARATION IN EL SEGUNDO TO HOXIE AVENUE UNDERCROSSING IN NORWALK |
QA Service Level | 1 (Verified on 06/18/2019) |
Sample Information
Sample Taken Date | 07/26/2019 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/07/2019 |
Sample type | Annual Source Testing | A brief description of the sample | Washed Concrete Sand |
The quantity of what the sample constitutes | 1 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Chris | Last name of sampler or witnessed by | Hindman |
Title of sampler | Quality Control | Telephone number of sampler | 951-493-6500 |
Laboratory sample identification | 8671 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Robertsons - Cabazon | Transportation Laboratory (TL) Number | C-19-000012 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-33-0008::CABAZON QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile at plant |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-07-26-16
DIME Test ID: 2019-07-26-16-12
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2019-09-05
Test Results
Number of tests: 2
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 08/23/2019
Temperature correction: 0
Temperature of solution: 73
Clay reading (test 1): 5.2
Sand reading (test 1): 4
Clay reading (test 2): 5.3
Sand reading (test 2): 4.2
Sand equivalent (test 1): 77
Sand equivalent (test 2): 80
Sand equivalent before temperature correction: 79
Sand equivalent after temperature correction: 79
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/5/2019 ✔