Summary for Test 2019-07-25-14-1

Test performed: AASHTO T11-5

Project Information

Project IdentifiersProject ID: 213877
DEA: 060X8904
EFIS: 0618000179
DIST-CO-RTE-PM06-KIN-41-0.0/11.5
Award Date03/15/2019
Closeout Date04/16/2021
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA TYPE G.
Location DescriptionKINGS COUNTY ABOUT 6.5 MILES SOUTH OF KETTLEMAN CITY FROM KERN COUNTY LINE TO 0.1 MILE SOUTH OF UTICA AVENUE
QA Service Level1 (Verified on 04/11/2019)

Sample Information

Sample Taken Date07/25/2019 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/29/2019
Sample typePer Request A brief description of the sample1/2" HMA
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed bySPM Last name of sampler or witnessed bySPM
Title of samplertech Telephone number of sampler
Laboratory sample identification19-HMA-0140 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSPM Avenal-Plant Transportation Laboratory (TL) NumberC816114-Lot 1-SL19
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)not supply
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot number1
Sublot number19 Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-07-25-14
DIME Test ID: 2019-07-25-14-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Test Release Date: 2019-09-04

Test Results


Input Type: Measured
Tester's full name: PM/RK/JH
Date of test: 08/29/2019
Which test procedure is being used: Method A
Mass of test sample (before test): 858.4 grams
Mass of test sample (after test): 796.4 grams
Percent of sample passing the #200 sieve (by mass): 7.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/4/2019