Summary for Test 2019-08-21-8-3

Test performed: ASTM D624-00-re12

Project Information

Project IdentifiersProject ID: 212596
DEA: 100L0204
EFIS: 1013000053
DIST-CO-RTE-PM10-SJ,STA-99-0.0-0.7:24.4-24.8
Award Date11/30/2018
Closeout Date07/15/2021
Work DescriptionPartial Bridge Replacement
Location DescriptionON ROUTE 99 IN RIPON AT THE COUNTY LINE OF SAN JOAQUIN COUNTY AND STANISLAUS COUNTY AT THE STANISLAUS RIVER BRIDGES (29-0013L/R).
QA Service Level1 (Verified on 12/19/2018)

Sample Information

Sample Taken Date08/21/2019 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2019
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byGeorge Last name of sampler or witnessed bySamuel
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDS Brown Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)1057402-2A
Material/Compound/Elastomer IDna Samples Representing29
Description (size)10" X 10" X 1.149" CommentsUnknown
Description (Number of Shims)2 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)DS Brown
Batch Numberna

Test Details

DIME Sample ID: 2019-08-21-8
DIME Test ID: 2019-08-21-8-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2019-09-04

Test Results


Number of specimens tested: 3
Input Type: Measured
Tester's full name: spaine
Date of test: 08/28/2019
Humidity: 50.00 %
Temperature: 72 F
Sample 1 Median Thickness: 0.066
Sample 1 Tear Strength: 246.17
Sample 2 Median Thickness: 0.067
Sample 2 Tear Strength: 248.3
Sample 3 Median Thickness: 0.063
Sample 3 Tear Strength: 248.45
UTM: 2kip
Median of the Tear Strength Values: 248.3 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Sample 3

Source: Bluehill Data Point File
Test graph for Sample 1

Source: Bluehill Data Point File
Test graph for Sample 2

Test was verified on 9/4/2019