Test 2014-07-30-5304335-2 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 208679
DEA: 100S1104
EFIS: 1000000229
COOP: 10406
DIST-CO-RTE-PM10-SJ-4,5-Var
Work DescriptionSR-4 FREEWAY EXTENSION
Location DescriptionIN SAN JOAQUIN COUNTY
Sample Information
Sample Taken Date7/30/2014 Sample Unique Key5304335
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/30/2014
Sample typeAnnual Source Testing A brief description of the sampleThree Eighths
The quantity of what the sample constitutes1 Bag From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byMcdermott
Title of sampler Laboratory sample identification14CPCC0268 C874539B
The fabricator/manufacturer/facility nameConfab Lathrop KRC Vernalis Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)NA
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2014-07-30-5304335
DIME Test ID: 2014-07-30-5304335-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2014-08-19
Test Results

What size aggregate is being tested?: 0.5 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Ed Perez
Date of test: 08/04/2014
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:95 %
Cumulative percent passing the #4 sieve:15 %
Cumulative percent passing the #8 sieve:2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/19/2014