Summary for Test 2019-08-01-3-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214122
DEA: 081G1204
DIST-CO-RTE-PM08-RIV-243-13.3/29.7
Award Date06/12/2019
Closeout Date03/25/2020
Work DescriptionCOLD PLANE AC, PLACE RHMA-G AND RECESSED THERMOPLASTIC TRAFFIC STRIPE.
Location DescriptionRIVERSIDE COUNTY IN AND NEAR BANNING FROM 0.7 MILE NORTH OF BLACK MOUNTAIN TRAIL TO ROUTE 243/10 SEPARATION
QA Service Level1 (Verified on 03/25/2020)

Sample Information

Sample Taken Date08/01/2019 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/02/2019
Sample typeVerification A brief description of the sample3/4 RHMA-G-SP
The quantity of what the sample constitutesJMF 6 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byMatich Cabazon Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0457G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertsons Cabazon, Cemex Lytle Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0008, 91-36-0040
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sampleCHP-68E
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Matich Cabazon Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-08-01-3
DIME Test ID: 2019-08-01-3-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-08-22

Test Results


Input Type: Measured
Tester's full name: Michael Magana
Date of test: 08/06/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 965.3 grams
Mass of the pycnometer with water (B): 655 grams
Mass of the oven dried sample (before pycnometer) (A): 491.9 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.9 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.593
Bulk specific gravity (SSD Basis): 2.636
Apparent specific gravity: 2.709
Absorption: 1.6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/22/2019