Summary for Test 2019-07-22-9-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 212300 DEA: 044G3804 EFIS: 0412000463 |
---|---|
DIST-CO-RTE-PM | 04-SON-116-30.9/31.4 |
Award Date | 03/15/2019 |
Closeout Date | 02/16/2024 |
Work Description | Construct Bridge, Retaining Walls, Traffic Signal |
Location Description | SONOMA COUNTY NEAR COTATI FROM 0.3 MILE EAST OF HESSEL ROAD TO 0.1 MILE EAST OF BARTLESON ROAD |
QA Service Level | 1 (Verified on 08/19/2019) |
Sample Information
Sample Taken Date | 07/22/2019 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/24/2019 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | two | From where was the sample collected | Job Site |
First name of sampler or witnessed by | B | Last name of sampler or witnessed by | None |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 239916 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 4700 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 00000000 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | Jobsite | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2019-07-22-9
DIME Test ID: 2019-07-22-9-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-07-29
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: JK
Date of test: 07/29/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 176719 lb
Maximum load on cylinder 2: 181479 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 7 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.45 in^2
Cross sectional area of cylinder 2: 28.45 in^2
Compressive strength of cylinder 1: 6211.6 psi
Compressive strength of cylinder 2: 6378.9 psi
Compressive strength (to nearest 10 psi): 6300 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 7/29/2019 ✔