Test 2019-06-29-5-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 213603
DEA: 07301504
EFIS: 0714000020
DIST-CO-RTE-PM07-LA-1,10-R34.6/35.2,R2.1/18.4
Work DescriptionREPLACING CONCRETE AND AC PAVEMENT
Location DescriptionLOS ANGELES COUNTY IN SANTA MONICA AND LOS ANGELES ON ROUTE 1 FROM 0.1 MILE WEST OF MAIN STREET OVERCROSSING TO ROUTE 1/10 SEPARATION AND ON ROUTE 10 FROM ROUTE 1/10 SEPARATION TO ROUTE 5/10 SEPARATION AND AT ROUTE 10/110 SEPARATION
Sample Information
Sample Taken Date6/29/2019 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/3/2019
Sample typeVerification A brief description of the sample3/4 RHMA-G-SP
The quantity of what the sample constitutesJMF 4 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Irwindale Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0405G-19
The fabricator/manufacturer/facility nameFish Canyon - Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035::FISH CANYON QUARRY
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample226108A IRW LTR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Vulcan Irwindale Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-06-29-5
DIME Test ID: 2019-06-29-5-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-08-22
Test Results

Input Type: Measured
Tester's full name: Nader Rashidi
Date of test: 07/11/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 964.3 grams
Mass of the pycnometer with water (B): 653.9 grams
Mass of the oven dried sample (before pycnometer) (A): 489 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 489 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.579
Bulk specific gravity (SSD Basis):2.637
Apparent specific gravity:2.738
Absorption:2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/22/2019