Summary for Test 2019-01-02-2-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 55555 DEA: AMRL EFIS: AMRL |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for AASHTO Materials Reference Laboratory (AMRL). |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/02/2019 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/02/2019 |
Sample type | Proficiency | A brief description of the sample | Proficiency Sample |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | AASHTO resource | Last name of sampler or witnessed by | AASHTO resource |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AASHTO resource | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Not Applicable |
---|---|---|---|
HMA Grading | Not Applicable | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-01-02-2
DIME Test ID: 2019-01-02-2-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-07-17
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Gurpartap Grewal
Date of test: 01/02/2019
Test procedure used?: Method B
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1554.5 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1472.1 g
Correction Factor (Percent by mass of HMA Specimen): 0.01 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.29 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/17/2019 ✔