Test 2019-06-25-24-5 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 212889
DEA: 073009U4
EFIS: 0714000238
DIST-CO-RTE-PM07-LA-110-R0.7/24.1
Work DescriptionREPLACE CONCRETE PAVEMENT, COLD PLANE AND PLACE HMA PAVEMENT.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES AND CARSON FROM GAFFEY STREET TO 0.1 MILE SOUTH OF COLLEGE STREET OVERCROSSING
Sample Information
Sample Taken Date6/25/2019 Sample Unique Key24
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/28/2019
Sample typeVerification A brief description of the sample3/4 RHMA-G-SP
The quantity of what the sample constitutesPSE 3 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byLoi Last name of sampler or witnessed byNguyen
Title of sampler Laboratory sample identification0388G-19
The fabricator/manufacturer/facility nameAll American Asphalt Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample106835
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-06-25-24
DIME Test ID: 2019-06-25-24-5
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2019-08-22
Test Results

Input Type: Measured
Tester's full name: Michael Magana
Date of test: 07/01/2019
Grading designation: C
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4772 grams
Mass of sample on No.12 sieve (after 500 revolutions): 3917 grams
Percent loss after 100 revolutions:5 %
Percent loss after 500 revolutions:22 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 08/22/2019