Summary for Test 2019-06-10-15-7

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 213388
DEA: 120N3004
EFIS: 1213000194
DIST-CO-RTE-PM12-ORA-241-18.3/18.7
Award Date09/26/2018
Closeout Date12/09/2019
Work DescriptionRAMP REALIGNMENT, PAVING, AND RE-STRIPING.
Location DescriptionORANGE COUNTY IN RANCHO SANTA MARGARITA FROM 0.2 MILE SOUTH TO 0.2 MILE NORTH OF SANTA MARGARITA PARKWAY OVERCROSSING
QA Service Level1 (Verified on 04/16/2019)

Sample Information

Sample Taken Date06/10/2019 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/11/2019
Sample typePer Request A brief description of the sampleClass 2 Aggregate Base
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byCuong Last name of sampler or witnessed byDo
Title of samplerTET Telephone number of sampler
Laboratory sample identification8608 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) Number8608
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-10-15
DIME Test ID: 2019-06-10-15-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2019-07-03

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/12/2019
Cumulative percent passing the 3/8 in. sieve: 73 %
Cumulative percent passing the #4 sieve: 55 %
Cumulative percent passing the #8 sieve: 42 %
Cumulative percent passing the #16 sieve: 32 %
Cumulative percent passing the #30 sieve: 24 %
Cumulative percent passing the #50 sieve: 18 %
Cumulative percent passing the #100 sieve: 13 %
Cumulative percent passing the #200 sieve: 9.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/3/2019