Summary for Test 2019-05-23-20-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 211775
DEA: 024E6504
EFIS: 0212000012
DIST-CO-RTE-PM02-SIS-96-R52.5/88.4
Award Date07/10/2017
Closeout Date01/05/2021
Work DescriptionWIDEN BRIDGES,POLYESTER CONC OVERLAY,COLD PLANE AC PVMT,HMA,GUARDRAIL
Location DescriptionSISKIYOU COUNTY NEAR SEIAD VALLEY AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF THOMPSON CREEK BRIDGE TO 0.2 MILE EAST OF BEAVER CREEK BRIDGE
QA Service Level1 (Verified on 08/23/2017)

Sample Information

Sample Taken Date05/23/2019 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/23/2019
Sample typeVerification A brief description of the sample3/4-inch Type A HMA (eq. PG 64-28 M) with WMA
The quantity of what the sample constitutesJMF Modification From where was the sample collectedManufacturer
First name of sampler or witnessed byDerrick Last name of sampler or witnessed byCurry
Title of sampler Telephone number of sampler
Laboratory sample identificationD77888 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFawndale Rock and Asphalt Transportation Laboratory (TL) Number001376
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number0
Sublot number0 HMA Mix NumberNot set

Test Details

DIME Sample ID: 2019-05-23-20
DIME Test ID: 2019-05-23-20-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-07-02

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Arthur Mills
Date of test: 05/23/2019
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 4.43 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/2/2019