Summary for Test 2019-04-22-6-1
Test performed: CTM 204-June 2010Project Information
Project Identifiers | Project ID: 213888 DEA: 024H2704 EFIS: 0218000101 |
---|---|
DIST-CO-RTE-PM | 02-SHA-44-34.0/43.2 |
Award Date | 03/21/2019 |
Closeout Date | 12/04/2019 |
Work Description | PLACE HMA (TYPE A) OVERLAY. |
Location Description | SHASTA COUNTY AT AND NEAR VIOLA FROM 0.2 MILE EAST OF MILL CREEK ROAD TO 0.8 MILE EAST OF DEER FLAT ROAD |
QA Service Level | 1 (Verified on 04/03/2019) |
Sample Information
Sample Taken Date | 04/22/2019 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/22/2019 |
Sample type | Verification | A brief description of the sample | Combined Untreated Virgin 1/2-inch Type A Aggregate |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Anthony | Last name of sampler or witnessed by | Ortiz |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D77841F | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Shasta Ranch Aggregates | Transportation Laboratory (TL) Number | 736648 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0057::SHASTA RANCH AGGREGATES |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | L190860 |
The plant number | Unknown | A detailed description of where the material sample was collected | Lab-Batched from Sized Untreated Aggregate Stockpiles |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | JMF 19-11-S1 | Lot number | 0 |
Sublot number | 0 | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-04-22-6
DIME Test ID: 2019-04-22-6-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2019-06-27
Test Results
The test method used?: Plastic Index
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/26/2019
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/27/2019 ✔