Test 2019-06-03-9-4 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
Sample Information
Sample Taken Date6/3/2019 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/7/2019
Sample typeVerification A brief description of the sample1/2 HMA-A-SP R25
The quantity of what the sample constitutesJMF 12 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byBlue Diamond Victorville Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0330A-19
The fabricator/manufacturer/facility nameBlue Diamond Oro Grande, Cemex White Mountain Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Blue Diamond Oro Grande, Cemex White Mountain
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R25 The fabricator/manufacturer designation for the sample300215 R25
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-06-03-9
DIME Test ID: 2019-06-03-9-4
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2019-07-03
Test Results

Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 06/10/2019
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 966.9 grams
Mass of the pycnometer with water (B): 655 grams
Mass of the oven dried sample (before pycnometer) (A): 492.6 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 492.6 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.619
Bulk specific gravity (SSD Basis):2.658
Apparent specific gravity:2.726
Absorption:1.5 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/03/2019