Test 2019-06-03-9-1 (AASHTO T27-14) Summary

Project Information
Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
Sample Information
Sample Taken Date6/3/2019 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/7/2019
Sample typeVerification A brief description of the sample1/2 HMA-A-SP R25
The quantity of what the sample constitutesJMF 12 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byBlue Diamond Victorville Last name of sampler or witnessed byQC
Title of sampler Laboratory sample identification0330A-19
The fabricator/manufacturer/facility nameBlue Diamond Oro Grande, Cemex White Mountain Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Blue Diamond Oro Grande, Cemex White Mountain
The fabricator's/manufacturer's product name for the sample1/2 HMA-A-SP R25 The fabricator/manufacturer designation for the sample300215 R25
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown JMF Verification ID
Test Details
DIME Sample ID: 2019-06-03-9
DIME Test ID: 2019-06-03-9-1
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2019-07-03
Test Results

What type of gradation is being tested?: HMA Gradation
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Input Type: Calculated
Tester's full name: Larry Diaz
Date of test: 06/20/2019
Cumulative percent passing the 1 1/2 in. sieve:100 %
Cumulative percent passing the 1 in. sieve:100 %
Cumulative percent passing the 3/4 in. sieve:100 %
Cumulative percent passing the 1/2 in. sieve:95 %
Cumulative percent passing the 3/8 in. sieve:86 %
Cumulative percent passing the 1/4 in. sieve:71 %
Cumulative percent passing the #4 sieve:66 %
Cumulative percent passing the #8 sieve:52 %
Cumulative percent passing the #16 sieve:36 %
Cumulative percent passing the #30 sieve:22 %
Cumulative percent passing the #50 sieve:10 %
Cumulative percent passing the #100 sieve:3 %
Cumulative percent passing the #200 sieve:2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/03/2019