Summary for Test 2019-05-13-15-2
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 212753 DEA: 020H7604 EFIS: 0215000086 |
---|---|
DIST-CO-RTE-PM | 02-LAS,PLU-VAR-VAR |
Award Date | 03/28/2019 |
Closeout Date | 09/02/2020 |
Work Description | FULL DEPTH RECLAMATION AND DRAINAGE REHABILITATION |
Location Description | LASSEN AND PLUMAS COUNTIES AT AND NEAR CHILCOOT FROM 0.9 MILE WEST OF SUMMIT SCHOOL DRIVE TO 0.7 MILE EAST OF ROUTE 395 |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 05/13/2019 | Sample Unique Key | 15 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2019 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA (eq. PG 64-28 M) |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Derrick | Last name of sampler or witnessed by | Curry |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D77883 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Ward Lake Plant | Transportation Laboratory (TL) Number | 001352 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 0 |
Sublot number | 0 | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-05-13-15
DIME Test ID: 2019-05-13-15-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-06-20
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 06/06/2019
Method Performed: no data
Mass of container filled with water: 7341.0 grams
Mass of oven-dry sample in air for Sample 1: 2543.0 grams
Mass of container filled with the sample and water for Sample 1: 8825.0 grams
Temperature of Water: 24 °F
Specific Gravity for Sample 1: 2.402
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/20/2019 ✔