Summary for Test 2019-06-10-6-8

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 213637
DEA: 07303304
EFIS: 0714000008
DIST-CO-RTE-PM07-VEN-1-0.0/4.4
Award Date11/13/2018
Closeout Date09/03/2020
Work DescriptionCOLD PLANE AND RHMA OVERLAY, GUARDRAIL, AND ROADSIDE SIGNS
Location DescriptionVENTURA COUNTY FROM LOS ANGELES/VENTURA COUNTY LINE TO SYCAMORE CANYON ROAD
QA Service Level1 (Verified on 04/16/2019)

Sample Information

Sample Taken Date06/10/2019 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/12/2019
Sample typeVerification A brief description of the sample3/4 RHMA-G-SP
The quantity of what the sample constitutesPSE 4 bags From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Saticoy Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0343G-19 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Palmdale Quarry Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0020::PALMDALE
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample226108 SAT - LTR
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-06-10-6
DIME Test ID: 2019-06-10-6-8
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2019-07-03

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/17/2019
Bulk dry specific gravity: 2.657
Average uncompacted voids: 48.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/3/2019