Summary for Test 2019-05-09-15-2

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 213336
DEA: 023E7404
EFIS: 0200020160
DIST-CO-RTE-PM02-SHA-299-R7.6/18.3
Award Date08/24/2018
Closeout Date09/02/2020
Work DescriptionPAVEMENT PRESERVATION
Location DescriptionSHASTA COUNTY AT AND NEAR SHASTA FROM 0.5 MILE WEST OF CRYSTAL CREEK ROAD TO TRINITY ALLEY
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date05/09/2019 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/13/2019
Sample typeVerification A brief description of the sample3/4-inch Type A HMA (eq. PG 64-28 M)
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJosh Last name of sampler or witnessed byWilliams
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD77879 Linked DIME Sample ID
The fabricator/manufacturer/facility nameValero - Benicia, CA Transportation Laboratory (TL) Number001911
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number0
Sublot number0 HMA Mix NumberNot set

Test Details

DIME Sample ID: 2019-05-09-15
DIME Test ID: 2019-05-09-15-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-06-18

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 05/13/2019
Method Performed: no data
Mass of container filled with water: 7341.0 grams
Mass of oven-dry sample in air for Sample 1: 2593.0 grams
Mass of container filled with the sample and water for Sample 1: 8902.0 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.514
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/18/2019