Summary for Test 2019-06-06-3-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 213267 DEA: 04013584 EFIS: 0416000289 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-8.0/8.3,0.9/1.4 |
Award Date | 03/29/2018 |
Closeout Date | 12/30/2019 |
Work Description | Pier Retention |
Location Description | In San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza |
QA Service Level | 1 (Verified on 05/01/2018) |
Sample Information
Sample Taken Date | 06/06/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/18/2019 |
Sample type | Quality Assurance | A brief description of the sample | A325N Bolt Assy |
The quantity of what the sample constitutes | 1 lot of 48 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Stacey | Last name of sampler or witnessed by | Davis |
Title of sampler | QAI | Telephone number of sampler | 5624806984 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Nucor Fastener Division | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-039-19 | Structure unique identifier | 33-0025 |
Structure name | SFOBB Pier Retention |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | N/A |
---|---|---|---|
Heat Number(s) | 100894945 | Nut Mfg. Lot Number(s) | 349781C |
Washer Mfg. Lot Number(s) | 1115-124 | Bolt Specification | A325N |
Bolt Length(s) | 1.75 | Nut Specification | Grade DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 418605A |
Rocap Test Requirement(s) | None | Lubricant Requirements(s) | yes |
Test Details
DIME Sample ID: 2019-06-06-3
DIME Test ID: 2019-06-06-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-06-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 06/17/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 349781C | 1/2\" | 21489 | 95.59 | Nut Proof Load | Steve |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 6/19/2019 ✔