Summary for Test 2019-06-06-4-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213267
DEA: 04013584
EFIS: 0416000289
DIST-CO-RTE-PM04-SF-80-8.0/8.3,0.9/1.4
Award Date03/29/2018
Closeout Date12/30/2019
Work DescriptionPier Retention
Location DescriptionIn San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza
QA Service Level1 (Verified on 05/01/2018)

Sample Information

Sample Taken Date06/06/2019 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/18/2019
Sample typeQuality Assurance A brief description of the sample3/4" bolt Assy
The quantity of what the sample constitutes1 lot of 10 From where was the sample collectedFabricator
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler5624806984
Laboratory sample identification Linked DIME Sample ID2019-06-06-3
The fabricator/manufacturer/facility nameNucor Fastener Division Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-039-19 Structure unique identifier33-0025
Structure nameSFOBB Pier Retention

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)N/A
Heat Number(s)NF161000668 Nut Mfg. Lot Number(s)391701C
Washer Mfg. Lot Number(s)0118-746 Bolt SpecificationA325N
Bolt Length(s)3.75 Nut SpecificationGrade DH
Washer SpecificationF436 FinishHDG
Diameter/Size3/4" Bolt Mfg. Lot Number376945A
Rocap Test Requirement(s)None Lubricant Requirements(s)Yes

Test Details

DIME Sample ID: 2019-06-06-4
DIME Test ID: 2019-06-06-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-06-19

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 06/17/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A376945A3/4\"50248223.510A325Steve

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 6/19/2019