Test 2019-05-20-2-1 (ASTM A370-15) Summary

Project Information
Project IdentifiersProject ID: 212245
DEA: 024F8604
EFIS: 0213000043
DIST-CO-RTE-PM02-TRI-36-26.7/27.1
Work DescriptionROADWAY REALIGNMENT AND NEW BRIDGE CONSTRUCTION
Location DescriptionTRINITY COUNTY ABOUT 9 MILES EAST OF FOREST GLEN FROM 0.6 MILE WEST TO 0.1 MILE WEST OF ROUTE 3
Sample Information
Sample Taken Date5/20/2019 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/24/2019
Sample typeQuality Assurance A brief description of the sampleF1554 Grade 55 Anchor Bolts
The quantity of what the sample constitutes87 From where was the sample collectedFabricator
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerTET Laboratory sample identification
The fabricator/manufacturer/facility nameEDSCO Fasteners Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB10-151-19 Structure unique identifier53-TRI
Structure name
Material Information
Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)177429 Nut Mfg. Lot Number(s)1-74983, 2-DDXL stamp 2HDH
Washer Mfg. Lot Number(s)310803 Bolt SpecificationF1554
Bolt Length(s)4'-2" Nut SpecificationA194
Washer SpecificationF436 Finish
Diameter/Size2" Bolt Mfg. Lot NumberNA
Rocap Test Requirement(s) Lubricant Requirements(s)blue dye nut heat 3074438
Test Details
DIME Sample ID: 2019-05-20-2
DIME Test ID: 2019-05-20-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2019-06-13
Test Results

Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/06/2019
UTM:67KIP
Temperature:72 f
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
111774290.50.196607788942026.9Fred

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 06/06/2019