Summary for Test 2019-05-20-26-4
Test performed: ASTM A931-0810Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/20/2019 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/20/2019 |
Sample type | Acceptance | A brief description of the sample | Wire Rope |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Other |
First name of sampler or witnessed by | Tapajr | Last name of sampler or witnessed by | Hector |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | 04 Toll Bridge Paint Crew | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM10 - Wire Rope Choker | Reel Number | 1 |
---|---|---|---|
Painter Name or ID | Hector, Carlos, Albert | Material Specification | ASTM A931 |
Size | 5/16 in | Wire Manufacturer | Cable More |
Material Collected to Test | Operator |
Test Details
DIME Sample ID: 2019-05-20-26
DIME Test ID: 2019-05-20-26-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A931-0810: Standard Test Method for Tension Testing of Wire Ropes and Strand (Breaking Force)
Test Release Date: 2019-06-12
Test Results
Input Type: Calculated
Tester's full name: Brian
Date of test: 06/05/2019
Temperature: 72 F
UTM: 67 KIP
Specimen Identification: Wire Rope
Peak Load: 8955 lbf
Operator: S144256
Location of Failure: Clamp
General comments (publicly viewable) (Max 1000 characters): Cable Pulled Out of Clamp
Test Graph
Source: Partner Data Point FileTest graph for 2019-05-20-26-4
Test was verified on 6/5/2019 ✔