Test 2019-05-20-22-9 (CTM 643-June 2007) Summary

Project Information
Project IdentifiersProject ID: 3825
DEA: 07138204
EFIS: 0700000142
DIST-CO-RTE-PM07-LA-47,103-3.5/4.6,0.0/1.1
Work DescriptionREPLACE STEEL BRIDGE WITH CIP PS CONCRETE BOX GIRDER BRIDGE AND RAMPS.
Location DescriptionLOS ANGELES COUNTY IN LONG BEACH AND LOS ANGELES ON ROUTE 47 FROM OCEAN BOULEVARD TO ROUTE 103 JUNCTION AND ON ROUTE 103 FROM ROUTE 47 JUNCTION TO ANAHEIM STREET OVERHEAD
Sample Information
Sample Taken Date5/20/2019 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing5/23/2019
Sample typePer Request A brief description of the sampleNative Soil
The quantity of what the sample constitutes1 bag From where was the sample collectedJob Site
First name of sampler or witnessed byAlexksey Last name of sampler or witnessed bySouglobov
Title of sampler Laboratory sample identification8597
The fabricator/manufacturer/facility nameCaltrans Transportation Laboratory (TL) NumberC 190520
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown
Test Details
DIME Sample ID: 2019-05-20-22
DIME Test ID: 2019-05-20-22-9
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2019-06-12
Test Results

The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: Kiet Phan
Date of test: 05/31/2019
Soil sample resistance (lab measure 1): no data Ohms
Soil sample resistance (lab measure 2): no data Ohms
Soil sample resistance (lab measure 3): no data Ohms
Soil sample resistance (lab measure 4): no data Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 120 Ohms
Soil sample temperature: 22.6 C
Soil box constant: 1
pH of soil: 7.77
Minimum soil resistance corrected to 15.5:141 Ohms
Minimum soil resistivity at 15.5:141 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 06/05/2019